=========================== FOLLOWING PSMSL DOCUMENTATION ADDED 05-Jun-1995 1992 revised, June 1995 =========================== FOLLOWING PSMSL DOCUMENTATION ADDED 03-Sep-1999 Acoustic gauge (Aquatrak 4100 series sensor) installed in 1998 =========================== FOLLOWING PSMSL DOCUMENTATION ADDED 05-Jun-2000 New analogue chart, float gauges were installed in 1985 in 4 Turkish stations: Antalya II, Bodrum II, Metes/Izmir and Erdek. All were replaced by new acoustic systems in 1998-99. =========================== FOLLOWING PSMSL DOCUMENTATION ADDED 05-Jun-2000 Bodrum II 310/046 RLR(1986) is 8.608m below BM MAR 1 =========================== FOLLOWING PSMSL DOCUMENTATION ADDED 01-Jul-2010 During May 2010 the complete revised data holding from the Turkish Sea Level Monitoring Network were supplied to the PSMSL from the General Command of Mapping.All datasets including that for Bodrum II were replaced. Previously RLR the values were TGBM BM MARI 3.475m above Chart Datum. RLR (1986) 8.608m below TGBM BM MARI. RLR factor 6.0m. A revised RLR diagram was created with Primary Benchmarl BDRM-1 2.578m above TGZ. RLR (2008) 8.3m below TGBM BDRM-1. RLR factor 5.722m Add 5.722m to all data values to refer to RLR (2008). There also exists a secondary benchmark BDRM-2. This is 2.407m above TGZ.